VOLTY-RS

Configuration and local data

Volty stores settings per Windows user and does not require administrator privileges. Use Show Advanced Options → Open Configuration to create or open %APPDATA%\Volty\config.toml. Volty watches the file for changes, and Discover Devices Now also reloads it. If a new configuration is invalid, Volty reports the error and keeps the last valid settings active.

low_battery_thresholds = [20, 10, 5] # 1-100 percent; normalized and deduplicated
low_battery_cooldown_minutes = 120 # repeat interval after the lowest threshold; 0 disables repeats
poll_interval_seconds = 120 # 10-3600 seconds after a successful reading
retry_interval_seconds = 15 # 5-300 seconds after an error
battery_eta_window_minutes = 10 # 1-180 minutes of discharge history
stale_after_minutes = 15 # 1-1440 minutes without a fresh reading before marking stale
notifications_enabled = true
log_level = "info" # error, warn, info, debug, or trace

# Optional tray color-map overrides. Thresholds are inclusive upper bounds.
# red_max_percent must be below yellow_max_percent; colors use #RRGGBB.
# [battery_color_map]
# red_max_percent = 15
# yellow_max_percent = 30
# red = "#d23030"
# yellow = "#ebbe23"
# green = "#2daa4b"

The old singular low_battery_threshold key is not accepted; replace it with low_battery_thresholds. Thresholds are constrained to 1–100, deduplicated, and sorted from highest to lowest. Each threshold fires once per discharge cycle. After the lowest threshold fires, the alert can repeat after each configured cooldown; 0 disables repeats.

The default tray colors are green above 30%, yellow from 16–30%, and red at 15% or below. Red and yellow cutoffs can be overridden (red: 0–99, yellow: 1–100) and must remain ordered. Omitted colors and thresholds retain their defaults.

Battery estimates and stale readings

Battery ETA appears after a full configured history window of discharging readings. It is hidden while charging or when the recent trend is unreliable. Volty also keeps a per-device long-run discharge rate based only on time the app was running and watching the device. After restart this may provide an ETA once at least an hour and two percentage points of discharge have been observed; the recent-window estimate takes over when available.

Tray labels show last-seen age after one minute and mark a reading stale after stale_after_minutes without a fresh reading. Labels refresh about once a minute, so a sleeping or disconnected device is not presented as live.

Logs

Choose Show Advanced Options → Open Log File to open the current daily log under %APPDATA%\Volty. Files are named volty-YYYY-MM-DD.log, rotate at 5 MiB with one .1 backup, and are retained for seven days. The default info level records lifecycle events and errors; debug adds successful battery readings; trace adds low-level details. Changes to log_level take effect when the configuration reloads.

Battery history

Monitored-device samples are stored locally in %LOCALAPPDATA%\Volty\battery-history.sqlite3. Samples are appended when a reading changes or at least five minutes have passed since its previous sample. Entries older than 30 days are pruned automatically. Recording failures are logged and do not interrupt polling. The database is never uploaded.

The native dashboard can pause or resume history recording for one device without changing whether Volty monitors it. Its per-device history cleanup removes stored samples; Forget all Volty data also clears that device’s Volty-owned monitoring, notification, rate, and pinned-device preferences.

Run volty history while the tray app is running to summarize the database; it does not open devices.

volty history
volty history --days 30
volty history --device receiver
volty history --csv > battery-history.csv

The default view covers seven days and reports sample count, first and last timestamps (UTC), latest/minimum/maximum percentage, and an estimated discharge rate when enough decreasing readings are available. --device filters by a case-insensitive substring of device identity or name; --database <path> reads a different database. CSV columns are timestamp_utc,identity,name,percent,charging,voltage_mv; unreported percent or voltage values are empty.